24 PositionSingle Phase electric / Energy Meter Test Bench
Accuracy class: 0.05/0.1
Standard power testing equipment:
SP-5100: Wide current reference standard energy meter
Accuracy class: 0.05 /0.1
Standard CT:0.01/0.02
Output voltage: 0-220V(240V option); range: 0-120%
Fine adjustment: 0.01%
Output current: 0-100A; (option for 200A)
Fine adjustment: 0.0001A (min)
Range of phase: 0-360° fine adjustment: 0.1°
Frequency: 45Hz-65Hz; fine adjustment: 0.01Hz
Waveform distortion coefficient: voltage/ current < 0.5%
Output stability of voltage, current, power: <0.05% (180S)
Output capacity (each phase): current: 800VA (120A), voltage: 400VA (24 meters)
Load: capacitance, resistance, inductance (≤4μF)
Starting current output: 10mA (min), accuracy: 5%, starting power: accuracy 10%
Numbers of calibrated energy meter: 24 (6/12/24/32/40/48 on requested)
Testing function: Basic error test; no load test; starting test; calibration tolerance test;
Input power: 220V AC10%, 50Hz; max. power consumption: 1500VA (24 meters)