Tower UPS - 220V Tower online UPS Power Supply
1: Tower UPS with 220/230/240V Input/Output
2: UPS Frequency 50/60Hz auto detect
3: Ture online Double Conversion UPS Technology
4: Pure Sine Wave Output online UPS Model
5: Large LCD Display for UPS Status
Tower UPS - 220V Tower online UPS Power Supply Key Features:
1: True on-line double conversion technology with advanced microprocessor control
2: Wide input voltage range
3: Zero transfer time
4: Protection against all type of power problems, Like: Power sags, high voltage spikes, switching transients, power surges, noise, frequency variation, brownout. Overload, Short Circuit, Overcurrent, Unbalanced Loads, Overvoltage
5: Self test while start of the UPS
6: Site wiring fault warning
7: On-battery power-on function
8: Smart RS232 and USB communication interface
9: Intelligent SNMP Card slot available
10: Built-in Sealed lead acid, maintenance free battery
11: Pure sine wave output
12: Single Phase In/Out for UPS 1-10KVA, Three Phase In and Single Phase out for UPS10-20KVA
13: Large LCD Display Large blue back light LCD for detailed real-time UPS status display
14: Microprocessor control guarantees high reliability
15: Comprehensive self-protection design
16: Audible alarm mute
17: Cold start function
18: Auto self-testing system while turning on UPS
19: Maintenance bypass switch for 6k to 20K
20: N + X parallel redundancy and capacity expansion for 6k to 20K
21: MCU (Freescale) +IGBT+DSP (TI) technology and double conversion structure.
UPS ModelEX1KEX1KLEX2KEX2KLEX3KEX3KLCapacity1000VA/800W2000VA/1600W3000VA/2100WInputVoltage(115~300)VACFrequency46~54Hz/56~64Hz (Adjustable via LCD panel)OutputVoltage220/230/240 (1±1%) VAC (Adjustable via LCD panel)Frequency50/60Hz (Adjustable via LCD panel)
50Hz AC Mode: Follow AC Mode (AC Range 46~54Hz): Battery Mode: 50Hz1±0.2%)
60Hz AC Mode: Follow AC Mode (AC Range56~64Hz): Battery Mode: 60Hz (1±0.2%)Output Wave FormPure Sine WaveBack-up TimeFull Load≥5′Depends on the capacity of the external battery bank≥9′Depends on the capacity of the external battery bank≥5′Depends on the capacity of the external battery bankHalf Load≥14′≥21′≥15′BatteryNominal DC Voltage36VDC96VDCTransfer Time0msOverload Capacity110%~150% maintain 30s then turn to bypass output, over 150% maintain 300msCommunicationsRS-232+Intelligent SlotEnvironmentTemperature0~40 CentigradeHumidity15%~90%Dimensions (W*D*H) mm145*400*220192*460*340Net Weight (Kg)1473413.534.514
Any more requirements about us,pls feel free to contact Bella