6 to 60kVA UPS
(1) online low frequency
(2) Input: 380Vac/3phase
(3) Output: 220Vac/1phase
Features:
1. Advance IGBT inverted technology
2. Multiple CPU intelligent control
3. Multiple protection function of over-voltage, short circuit, over-temperature
4. LCD front panel
5. Speical industrial design to ensure the safety in worse environment
6. Reliable, filtering and stable sine wave output
7. Cold start with DC function, unmanned function
8. online double-conversion, with output isolation transformer
PQZ2K~20K (1phase in and 1phase out)Mode:PQZ1KPQZ2KPQZ3KPQZ6KPQZ10KPQZ15KPQZ20KCapacity (VA/W)1K/0.8K2K/1.6K3K/2.4K6K/4.8K10K/8K15K/12K20K/16KInput VoltageSingle phase with two Lines+ground wire, 230V± 25%Noise≤ 52dB(distance 1m)≤ 60dB(distance 1m)Size530x 264x 592630x 343x 700(Dx Wx H, mm)Weight (Kg) (w/o battery)30657080145160180PQZ6K3~60K3 (Three- in and single- out)Mode:PQZ6K3PQZ10K3PQZ15K3PQZ20K3PQZ30K3PQZ40K3PQZ50K3PQZ60K3Capacity (VA/W)6K/4.8K10K/8K15K/12K20K/16K30K/24K40K/32K50K/4060K/48KInput VoltageThree phase with four Lines+ground wire, 380V± 25%Noise≤ 60dB(distance 1m)≤ 65dB(distance 1m)Size620x 343x 995650x 700x 1510(Dx Wx H, mm)Weight(Kg) (w/o battery)130165180220400450530620Common parametersInputFrequency50Hz /60Hz ± 10%Power factor≥ 0.95OutputVoltage220V± 0.5%Voltage regulationStable ± 1%, dynamic ± 2%, (< 20ms for 0-100%load change)Frequency stabilization50Hz /60Hz ± 0.5% (Battery Mode)Frequency slow rate< 1Hz / secondTransient response± 0.4% (100% instant load fluctuation)THD< 3% for linear load; < 5% for non-linear load Overload 110%~150% for 10seconds; > 150% for 1secondWave formTrue sine waveEfficiencyInput AC to output AC> 90%Transfer timeAC mains fails and/or restores0second UPS to BYPASS< 4 msBatteryVoltage192VCharge time8 hrs' recharge to 90% capacity Alarm Battery dischargeBeeps once every 4 seconds when battery discharge Beeps once every 1 second when battery low.Beeps continuously when battery discharge stopUPS faultBeeps continuouslyProtectionBattery lowAuto shutdown when battery low without fuse protection.Overload110~150% overload for 10 seconds, then auto jumps to BYPASS; Auto resumes when overload removedOver temperatureAuto jumps to BYPASS when UPS internal temperature > 85° COutput short circuitCurrent limits, auto shutdown, no fuse switch protection.UPS faultAuto jumps to BYPASSNoise Filter< 0}10~10KHz at 40 db; 100KHz~100MHz at 70 dbDisplayLCD Input and output voltage, frequency; battery voltage and output power (%), etcLED (BLV)LED (BLV) turns on when battery voltage low.AmbientTemperature0~40degCRelative humidity10%~90% (No condensation)Altitude 1500 meters