Automatic Transfer Switch, ATS, Change Over Switch manufacturer / supplier in China, offering PC Class ATS Change-Over Switch 16-3200A Automatic Transfer Switch for Generator, Sq5 Manual Changeover Switch ATS Electrical Changeover Switch, 20ka-40ka DC500V Solar DC Surge Protector and so on.
Min. Order / Reference FOB Price | |
---|---|
1 Piece | US $1.50/ Piece |
Local Area: | Wenzhou, Zhejiang, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, PayPal, WesternUnion, Small-amountpayment |
Brand: | Suntree |
---|---|
Breaking Capacity: | Low Voltage Circuit Breakers |
Operation: | Electric Type |
Speed: | Normal Type Circuit Breaker |
TypeC65-DPNNumber of poles1PRated Current(A)1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40,50,63ABreaking Capacity(A)4500/6000Rated Voltage(V)220/ 240VRated Frequency(Hz)50/60HzEndurance≥4000Tripping characteristicsB 3In ~ 5In; C 5In ~ 10In
Technical DataIEC 898Standards1P/2P/3P / 4PPolesCMagnetic tripping characteristics6 10 16 20 25 32,40,50,63ARated current(A)6kARated short-circuit capacity(Icn):DC250V DC550V DC750V DC800V DC1000V DC1200VRated voltage6kVRated withstand voltage (Uimp):1000Rated insulation voltage(Ui):YesContact position indication3Energy limiting class:>2000Electrical Life:>1500Mechanical Life:Screw terminalConnection terminal:Pillar terminal with clamp
1~16mmConnection capacity:Symmetrical DIN rail 35mmInstallation:Panel mounting
OF: Auxiliary contactAccessories:FB: Auxiliary alarm
QY: under/over volage protector
FL: Shunt release
TestTypeCurrentStart StateTrip / Not-trip
Time LimitExpected
ResultNoteac1.05 lnColdt ≥1hNot-trip
bc1.30 lnFoollows test at<1hTripThe current will rise to expected value within 5Scc7 lnColdt ≥0.1sNot-trip
dc15lnColdt<0.1sTrip
Operating Voltage (Ue)1P=125V DC or 250V DC, 2P=550V DC or 800V DC
3P=750V DC or 800V DC, 4P=1000 V DC or 1200V DCRated insulation voltage (Ui)12V-1200 VDCBreaking capacity (Icu)10 kAImpulse voltage (Uimp)6 kAElectrical connectionBy the bottom for In and OutNumber of poles1P, 2P, 3P, 4PStandardsIEC 60947-2
EN 60947-2
SAA
CE
TUV
Rated service breaking capacity (Ics)100 % of the IcuEndurance (O-C)Electrical1,500 cycles (where L/R=2 ms)Mechanical20, 000 cycles
Mechanical20, 000 cyclesDegree of pollution2CategoryA (no delay in accordance with IEC / EN 60947-2 standards)Degree of protection
(IEC 60529)IP40TropicalisationRelative humidity: 95 % at 55°C in accordance with
IEC 60068-2 and GB 14048.2 standardsTemperatureOperating-25°C to 70 °CStorage-40°C to 85°C
TypeDZ47 C45, C45NNumber of poles1P, 2P, 3P, 4PRated Current(A)1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63ABreaking Capacity(A)6000/ 4500Rated Voltage(V)230/400VRated Frequency(Hz)50/60HzEndurance≥4000Circumstance Temp.(°C)-5°C ~ +40°CElectrical Life≥6000Mechanical Life≥20000Terminal protectionIP20
TypeC65-DPNNumber of poles1PRated Current(A)1, 2, 3, 4, 6, 10, 16, 20, 25, 32ABreaking Capacity(A)4500Rated Voltage(V)220/ 240VRated Frequency(Hz)50/60HzEndurance≥4000Tripping characteristicsB 3In ~ 5In; C 5In ~ 10In
TypeC65 C60Number of poles1P, 2P, 3P, 4PRated Current(A)1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63ABreaking Capacity(A)6000/ 4500Rated Voltage(V)230/400VRated Frequency(Hz)50/60HzEndurance≥4000Circumstance Temp.(°C)-5°C ~ +40°CElectrical Life≥6000Mechanical Life≥20000Terminal protectionIP20
TypeNC100Number of poles1P, 2P, 3P, 4PRated Current(A)32, 40, 50, 63, 80, 100, 125ABreaking Capacity(A)10000Rated Voltage(V)230/400VRated Frequency(Hz)50/60HzEndurance≥4000Circumstance Temp.(°C)-5°C ~ +40°CElectrical Life≥6000Mechanical Life≥20000Terminal protectionIP20
TypeSL7Number of poles1P, 2P, 3P, 4PRated Current(A)1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63ABreaking Capacity(Icu)6KA/ 10KABreaking capacity of rated operating short circuit(Ics)7500ARated Voltage(V)230/400VRated Frequency(Hz)50/60HzCircumstance Temp.(°C)-5°C ~ +40°CElectrical Life≥8000Mechanical Life≥20000Type and tripping current scope of instantaneous releaseB 3In ~ 5In; C 5In ~ 10In; D 10In ~ 50InTerminal protectionIP20