2012 Technical datas:
-Power supply:230V ac 50-60Hz 1100W max
-Flashing beacon output:230V ac 500 W max
-Motor output:230V ac 500W max
-Auxiliary power output:24V ac 3W max
-Stop limit and low voltage commands:24V cc
-Working temperature:-10 55 celsius
-Radio receiver:see model
-Op.transmitters:12-18 Bit or Rolling Code
-Max stored TX codes:215(CODE+CODE PED)
-Box dimension:110*121*47mm
-Container:ABS V-0(IP54)
Functional Data:
Step-by-step Operation:
Using both the radio control(CODE LED illuminated) and the low voltage push-button station(PUL) to control the gate,the following operation is obtained:
the first impulse opens the gate until the motor timer reaches zero or until the opening stop limit is reached,the second impules closes the shutter,if an impulse arrives before the opening stop limit is reached,the control unit stops motion during both opening and closing.A futher command restarts motion in the opposite direction.
Automatic closing:
The control unit can close the gate automatically without sending additionalcommands.
The selection of this operation mode is described in the pause
Time programming mode.