GF102 PORTABLE SINGLE PHASE ENERGY METER TEST BENCH
GF102 portable single phase energy meter testing bench used to test single phase energy meter. Adopt mature signal synthetic and power amplifier technology, high precision voltage and current output. Widely used in lab and field, and then as single phase standard source.
FEATURESMeter under testing: 1P2W2Testing mode: active power, reactive powerTest 3pcs or 2pcs meter synchronouslyStart testing and creep testingReference standard and power source integrated, easy to carryMeasuring mechanical meter and electric meterOperating by manual keyboard or PC softwareWith keyboard shortcutsInternal large capacity storage device for mass memoryLocal checking the testing resultOverload, short circuit, open circuit protectionWith self-checking functionPARAMETERS
Electrical parameters | Accuracy class 0.05%, 0.1%Power supplyOne Phase AC 100-265V, frequency 50/60Hz.
AC Voltage Output | Range57.7V, 100V, 220V, 380V; max 500VAdjustment range(0-120)%RG(1)Adjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.Stability0.01%/120sDistortion0.1% (Non-capacitive load)Output loadmax 25VAMeasuring accuracy0.05%RG
AC Current Output | Range200mA, 1A, 5A, 20A, 100A; max 120AAdjustment range(0-120)%RGAdjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.Stability<0.01%/120sDistortion≤0.1% (Non-capacitive load)Output loadmax 50VAAccuracy0.05%RG
Power Output | Active power output stability<0.01%RG/120sReactive power output stability<0.02%RG/120sActive power measuring accuracy0.05%RGReactive power measuring accuracy0.1%RG
Phase Output | Output adjustment range0°-359.999°Output adjustment fineness10, 1, 0.1, 0.01 as optional.Resolution0.01°Accuracy0.05°
Power Factor | Adjustment range-1 ~ 0 ~ 1Resolution0.0001Measurement accuracy0. 0005
Frequency Output | Adjustment range40Hz-70HzOutput adjustment fineness5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.Resolution0.001HzAccuracy0.005Hz
Voltage /Current/Harmonic Setting | Harmonic number2-51timesHarmonic content0-40%Harmonic phase0-359.99Harmonic setting accuracy(10%±0.1%)RD(2)
Power Energy Measurement Error | Active power energy0.05%RGReactive power energy0.1%RG
Power Pulse Output | Power pulse typeactive pulse, reactive pulseActive power pulse output5V,10mA
Power Pulse Input | Energy pulse typesupport active and reactive pulse, the highest frequency
power pulse input is 180K.
Mechanical parameters | Dimensions (WxDxH) (mm)455x440x150Weight (kg)12
Environmental conditions | Ambient temperature-10°C to +40°CRelative humidity35%-85%(1)RG means range, the same as below;
(2)RD means the setted harmonic content, harmonic can be a single output,also multiple output.