Data Logger, Temperature Recorder, Temperature Data Logger manufacturer / supplier in China, offering Pdf Single Use Temperature Data Logger, Pdf Temperature and Humidity Data Logger with LCD, Ec-770 F/N Coating Thickness Gauge 1~3% Accuracy 1500um 5000um and so on.
Min. Order / Reference FOB Price | |
---|---|
10 Piece | US $72.00/ Piece |
Local Area: | Shenzhen, Guangdong, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, PayPal |
Sensor Probe Type: | Fe / Nfe Probes |
---|---|
Measurement Range: | 0 to 1500um |
Measuring Mode: | Single and Continuous |
ModelEC-770EC-770FEC-770NProbeF-Probe & N-ProbeF-ProbeN-ProbeMeasuring PrincipleMagnetic induction & Eddy CurrentsMagnetic inductionEddy CurrentsMeasuring Range0 to 1300 um Accuracy± (3%+2 um); ± (3%+0.078 mil)Resolution0 um~999 um(1 um) 1000 um~1300 um(0.01 mm)
0 mils~39.39 mils(0.01 mil) 39.4 mils~51.2 mils(0.1 mil)CalibrationOne point to four point calibration, zero point calibrationData GroupOne direct group(readings not be stored to memory)
Four general groups (readings will be stored automatically)
NOTE: each group have individual statistics, alarm limit settings and calibrationStatisticsNo. of readings, mean, minimum, maximum and standard deviationUnitsum, mm, milAlarmUser can set the high/low alarm limit ; Alarm icon displayed on LCD when over the limitMinimum Curvature Radius Convex1.5 mmMinimum Curvature Radius Concave25 mmMinimum Measuring AreaDiameter 6 mmMinimum Thickness Of SubstrateF-probe: 0.5 mm(0.02");N-probe: 0.3 mm(0.012")0.5 mm(0.02")0.3 mm(0.012")Maximum Measuring RateTwo readings per secondComputer InterfaceDownload data via USBPower SupplyTwo 1.5 V AAA batteryOperation EnvironmentTemperature: 0 to 40°C(32 to 104°F); Humidity: 20% to 90%RHStorage EnvironmentTemperature: -20 to 70°C(-4 to 158°F)Standard CertificationROHS; WEEE; CEDimensions110 mm*53 mm*24 mm(4.33"*2.09"*0.94")Case Material And WeightABS; 92 g
1. Is the measuring error large?
• Enter the menu interface, clear the calibration data; shut down torestore the factory configuration steps; do zero calibration after booting, (Note: you need to dozero calibration on the customer's own substrate)
2. Does the measurement screen display overflow?
•The coating thickness exceeds the measurement range.
•There is an error and zero calibration is required on the substrate.
•Probe fault
3. Measurement no response?
•Check if the battery has power.
•The probe has a fault.
•Whether the measured material meets the measurement principle.
4. Does the measurement show a negative number?
•It is judged according to the customer's materials whether the machine accuracy is applicable.
•The calibration did not do well and needs to be recalibrated.
5. During the measurement process, is it sometimes display F, sometimes display N?
• The automatic mode undistinguishable the type of material and it requires manual switching of the measurement principle.
6. How to do calibration?
•Please refer to the zero calibration, point calibration step.
7. Long press "ZERO" does not respond?
• You need to restore the factory settings and then operate.
8. It can measurement but there is no reading, why?
•Confirm whether the mode is in continuous measurement mode
•Check if the beep is broken