GF1061 Portable Precision Current Transformer Testing CT PT Analyzer With BatteryGF1061 portable CT PT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The CT PT Analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE and IEC standards.
Main functions
I. Current Transformer (CT) | II. Voltage Transformer (PT) | 1. Magnetization curve1. Excitation characteristic test2. Transformation ratio test2. Transformation ratio test3. Polarity3. Polarity4. 5% and 10% error curve4. Ratio error, phase error5. Accuracy limiting factor (ALF)Ball Screw 5. Degauss6. Degauss6. Calculation of knee point value7. Ratio error, phase error7. Actual secondary load test (burden test)8. Automatic calculation of excitation knee
point value8. Resistance test9. Actual secondary load test (burden test)10. Resistance test11. Secondary time constant (Ts)12. Remanence coefficient (Kr)13. Transient dimensioning factor (Ktd)14. Peak instantaneous error (Er)15. Magnetizing inductance (LU)16. Instruments security factor(FS)17. Composite errorParametersElectrical parameters | Accuracy0.05%Power supplyAC 220V±10% or AC 120V±10%, 50/60Hz or BatteryOutput voltage0-100VrmsOutput current0-5Arms (20A peak-value)Output power0-400VA (1500VApeak)Automatic frequency vEmergency Light & Indicator Light ariation range0.1-60HzEquivalent excitation voltage≤5000VAccuracy≤0.5%Secondary winding DC resistance measurementRange0.1-1000ΩAccuracy≤0.05%Secondary actual load measurementRange5VA-1000VAAccuracy≤0.5%±0.1VACT/PT pShaft hase error measurementAccuracy±1min (typical) / 3 min (guaranteed)ResolutiFeeder on0.1minCT ratio error measurementRange1-50000Accuracy≤0.05%PT ratio error measurementRange1-10000Accuracy≤0.05%Standards | Reference standardsGB1207-2006, GB1208-2006, GBMedical Diagnosis Equipment 16847-1997
IEC60044-1, IEC60044-6, IEC61869-2, ANSI/IEEE C57.13Safety standardsGB 4793.1-2007EMCEMC standard 89/336/EECFCC Subpart B of Part 15 Class AIEC 1000-4-2 /3 /4 /6Mechanical parameters | Overall dimension (L x W x H) (mm)280 x 250 x 160Weight (kg)≤4Environmental conditions | Relative humidityRelative humidity 5%-95% not condensingOperating temperature-10°C to +50°CStorage temperature-20°C to +70°CAltitude≤1000m
http:https://www.gfuve.com/transformer-test/portable-ct-analyzer.html