100KW online UPS/100KW solar UPS/100KW home UPS inverter
Our competitive advantage:
1. Inveter use copper transformer, 87-90% efficiency;
2. LCD/LED display;
3. 18months warranty, during the warranty, we send free PCB to maintance.
Feature:
Capacity: 1KW--100KW
(1) super wide input voltage: 285V-475V
(2) completely controlled by CPU, LCD automatic page turning display
(3) protection against output short-circuit; Against overload, and when you throw off its load, it will turn on the unit automatically.
(4)working for single phase and three phase.
110V/220V single phase; 240V/380V/415V/440V option.
(5) with charger built-in, its charging current is 10A----156A.
(6) different DC voltage: 24V, 48V, 96V, 384V for optional
(7) make it with 3 PCS PCB box, it is more stable design.
(8) this kinds inverter can take pump or lift, and other industrial use
ModelT1KT3KT5KT10KT15KT20KT30KT60KT100KPower1KW3KW5KW10KW15KW20KW30KW60KW100KWPower Factor0.8Input Phase3 phase 4 wire and ground Voltage Range380V± 20%(3 phase), phase voltage 220V Frequency Ranger45 - 65Hz Rectifier3 phase 6 pulses, 12 pulses is optionalOutput Phase3 phase 4 wire and ground Wave formPure sine wave Crest Factor3: 01 Rated voltage380/400/415V optional Phase voltage setting200 - 244VAC, Transient response+/-5%, 10ms Frequency50 / 60 Hz + / - 0.05% Total-harmonic distortion< 3% linear load, < 5%( nonlinear load) Short circuit currentShort current for 0.1s (200% current) Overload capacityOverload 125% for 10 ms, 125%-150% for 1min. automatically resume when load become normalBattery BatteryMaintenance free lead-acid cell DC Voltage48v or 96V(1-15KW)384V Max Charge Current6-30A adjustableBypass TypeStatic state + manual maintenance bypass Input Phase3 phase 4 wire and ground Input voltage range15% - 25% (the front control panel selectable) Transfer timeInverter / bypass transfer switch time(Overload): 0ms inverter / bypass transfer switch time (fault inverter) 1msEfficiency
Whole unit> 85% Inverter919192929393959595 Remote signalingDry contact (battery low, battery discharging, bypass/ fault); output 12Vdc/80mA, Optional parts Communication interfaceRS232 ( SNMP, modem optional ) Running temperature0-40 degree Celsius Relative HumidityLess than 95% (without condensing) Noise at 1 Mless than 60 dB Degree of protectionIP20 Applicable StandardsEN50091-1-EMC EN50091-2liv. A Product size(mm)560*230*570590*470*730900*600*13801200*900*1820 product weight(Kg)304054104125190380690800 Package size(mm)640*300*730690*570*8501135*810*14301450*1110*1880 Package weight(Kg)325060123145215420750860